CryoProbe Applications

Polymers

CryoProbes forPolymer Research

The Polymer CryoProbe is specifically designed to revolutionize polymer NMR analysis. By offering up to a 4 fold increase in sensitivity and a z-gradient this probe promises to reveal information on polymer structure that elutes the technology currently employed in most laboratories. Sized to accept 10mm samples and with an extended temperature range this probe incorporates specific features of importance to polymer researchers. With a temperature range of 0° to 135°C the use of high temperature NMR to increase molecular motion and provide narrow linewidths is achievable. Although configured optimally for 13C observation the dual configuration allows for excellent 1H observation as well. Being equipped with a z-gradient this probe is prepared to use pulse field gradient experiments to provide detection of 2D and 3D NMR cross peaks from minor structural components in organic polymers all with remarkable sensitivity or speed.
 

Uses of this probe include:

  • Polymer chain structure analysis
  • Competitive polymer product analysis
  • Additive identification and quantification
  • Compositional analysis of polymer formulations
  • Branching and unsaturation content analysis
  • Sequence distribution and tacticity analysis
  • Kinetics and thermal dynamics analysis
     

High Temperature HDPE Polymer spectra Avance II 600 MHz, 10 mm DUL CryoProbe, Z-Gradient; High Density Polyethylene in (HDPE) ODCB/TCE-d2

High Temperature HDPE Polymer spectra  Avance II 600 MHz, 10 mm DUL CryoProbe, Z-Gradient; High Density Polyethylene in (HDPE) ODCB/TCE-d2

High Temperature HDPE Polymer spectra - Avance II 600 MHz, 10 mm DUL CryoProbe, Z-Gradient; High Density Polyethylene in (HDPE) ODCB/TCE-d2

High Temperature HDPE Polymer spectra -  Avance II 600 MHz, 10 mm DUL CryoProbe, Z-Gradient; High Density Polyethylene in (HDPE) ODCB/TCE-d2

Avance II 600 MHz DUL 10 mm Z-Gradient CryoProbe - 50mM Quinine in DMSO-d6 5 &degexcitiation, ns=1, 1H Lineshape:TMS, nonspinning 0.64 Hz 14 / 35 Hz

Avance II 600 MHz DUL 10 mm Z-Gradient CryoProbe -  50mM Quinine in DMSO-d6 5 &degexcitiation, ns=1, 1H Lineshape:TMS, nonspinning 0.64 Hz 14 / 35 Hz

Avance II 600 MHz DUL 10 mm Z-Gradient CryoProbe - 50mM Quinine in DMSO-d6, 3D TOCSY-HSQC (13C) with 45 ms mixing, ns=2, 1k x 96 x 160; experimental time: 10 hours

Avance II 600 MHz DUL 10 mm Z-Gradient CryoProbe - 50mM Quinine in DMSO-d6, 3D TOCSY-HSQC (13C) with 45 ms mixing, ns=2, 1k x 96 x 160; experimental time: 10 hours